| Description: |
High build, solvent free, two component, tar modified polyurethane with outstanding
physical properties in terms of flexural strength, tensile strength, impact, abrasion
and penetration resistance. A rapid cure, very short pot life version for use with
automatic/line travel spray equipment is also available (see Data Sheet A24).
| |
|
Uses: |
Protection of steel and concrete structures in aggressive environments, i.e. internal
and external protection of pipelines, offshore splash zones, chemical plants, piling,
effluent tanks, etc.
|
| Color: |
Black |
| Volume Solids: |
100%
|
|
| Flash Point: | DIN 51758: Base: |
200¡ãC (390¡ãF) |
| ¡¡ | Activator: |
200¡ãC (390¡ãF) |
| Mixing Ratio: |
4:1 by volume |
| Application Method: |
Approved twin component hot airless spray machine. Brush for minor areas. |
| Pot Life: |
Approximately 5-7 minutes at 20¡ãC (68¡ãF) 120 g mass |
| Bond Strength: |
Steel: |
DIN 53232 70 kg/cm2 |
| ¡¡ |
¡¡ |
DIN 53151 (Cross cut) Glass G1 |
| Shrinkage: |
Negligible |
| Impact: |
ASTM 2794-69/14: 10 NM |
| Tensile Strength: |
DIN 53504: 10-13 N/mm2 |
| Elongation: |
ASTM D2370: 20-35% |
| Cathodic Disbondment: |
Electrolyte - Sodium Chloride (3% w/v): |
| DIN 30671: 30 days at 23¡ãC (73¡ãF) - 1200 mv (H2), thickness 1.0 mm - Pass |
| DIN 30671: 2 days at 65¡ãC (149¡ãF) - 1200 mv (H2), thickness 1.0 mm - Pass |
| British Gas PS/CW6: 28 days at 20¡ãC (68¡ãF) - 1500 mv (calomel) |
| Thickness 1.5 mm - Pass |
| Shore D Hardness: | 65-70 approximately |
| Penetration: |
DIN 30671: Under 30% |
| Flexibility: |
British Gas PS/CW6: Pass |
| Water Vapor
Permeability: |
DIN 52615: .005 metric/perm cm |
| Film Thickness: |
Can be applied at 0.5-5.0 mm in one continuous wet on wet application.
Specified thickness is dependent upon service conditions. |
| Temperature: |
Application: |
Minimum 0¡ãC (32¡ãF) ambient |
| ¡¡ |
Service (Dry): |
Minimum -20¡ãC to 110¡ãC (-4¡ãF to 230¡ãF) continuous |
| ¡¡ |
Service (Immersion): |
0¡ãC to 80¡ãC (32¡ãF to 176¡ãF) depending on solution |
| Drying Times at 20¡ãC
(68¡ãF): | Surface: | 40-60 minutes |
| Hard: | 4-8 hours |
| Stackable: | 16-24 hours |
| Recoat/Repair: | Maximum 24 hours (without further surface preparation) |
|
|
| |
| Ultimate Cure: |
14 days at 25¡ãC (77¡ãF), at lower
temperatures the curing rate will be slower
|
| Coverage: |
Theoretical: 1 m_/liter at 1 mm thickness
Suggested Practical: 0.75 m_/liter, will vary depending on the complexity of the
structure being coated and nature of the substrate
|
| Shelf Life: |
12 months |
| Solvent: |
Acothane 380 Solvent or Xylene is a recommended cleaning/purging fluid, where a
flash point of 23¡ãC (73¡ãF) can be tolerated. D.O.P. May be used as a purge fluid
when spraying if non-flammable material is necessary. Flash point: 208¡ãC (406¡ãF).
Under no circumstances must paint be thinned prior to application.
|
| Surface Preparation: |
| Steel: |
Ensure surfaces are clean, dry and free from contaminants. Grit blast to BS7079
Standard Sa 2.5 to an amplitude of 50-100 microns.
|
| Concrete: |
Remove all laitence and other contaminates by most appropriate method, i.e. blast
cleaning. Ensure concrete is dry to protimeter reading of less than 5 on the concrete
scale. Seal with U-Coat 501.
|
| Health and Safety: |
Refer to Material Safety Data Sheet No. A36 |
** Information contained in this publication is accurate to the best knowledge and belief of Lonestar Specialties, LLC Any information or advice obtained from Lonestar Specialties, LLC is also given in good faith and it remains at all times the responsibility of the customer to ensure that the materials are suitable for the purpose intended. Due to a policy of continued development work, and according to the availability of raw materials, products may differ in detail from those described and are offered subject to the Company's conditions of sale.
¡¡ |
¡¡ |